Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 25.521
2.
PLoS One ; 19(5): e0302828, 2024.
Article En | MEDLINE | ID: mdl-38722930

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Hemodynamics , Muscle, Skeletal , Oxyhemoglobins , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Hemodynamics/physiology , Female , Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Oxyhemoglobins/metabolism , Oxyhemoglobins/analysis , Cupping Therapy/methods , Young Adult , Hemoglobins/metabolism
3.
J Cardiothorac Surg ; 19(1): 284, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730503

INTRODUCTION: Post liver transplantation (LT) patients endure high morbidity rate of multi-organ ischemic symptoms following reperfusion. We hypothesize that enhanced external counterpulsation (EECP) as a typical non-invasive assisted circulation procedure, which can efficiently inhibit the relative ischemic symptoms via the systemic improvement of hemodynamics. CASE PRESENTATION: A 51-year-old male patient, 76 kg, 172 cm, received orthotopic LT surgery for viral hepatitis B induced acute-on-chronic liver failure hepatic failure. His medical records revealed ischemic symptoms in multi-organ at the time of hospital discharge, including headache, refractory insomnia, abdominal paralysis, and lower limb pain. The EECP treatment was introduced for assisted rehabilitation and to improve the postoperative quality of life. Doppler Ultrasound examination showed significant augmentation of blood flow volume in the carotid arteries, the hepatic artery, the portal vein and the femoral artery during EECP intervention. A standard 35-hour EECP treatment led to significant improvement in quality of life, e.g. sleep quality and walking ability. CONCLUSION: We report a case of multi-organ ischemic symptoms in a post LT patient. EECP treatment can significantly improve the quality of life via the systematic promotion of hemodynamics.


Counterpulsation , Hemodynamics , Liver Transplantation , Humans , Male , Middle Aged , Counterpulsation/methods , Hemodynamics/physiology , Postoperative Complications/therapy , Quality of Life , Ischemia/surgery , Ischemia/physiopathology
4.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Article En | MEDLINE | ID: mdl-38707651

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Cerebrovascular Circulation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Spectroscopy, Near-Infrared/instrumentation , Female , Male , Adult , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Oximetry/methods , Oximetry/instrumentation , Oxygen/blood , Oxygen/metabolism , Brain/diagnostic imaging , Brain/blood supply , Equipment Design
6.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Article En | MEDLINE | ID: mdl-38710669

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Aortic Valve , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hemodynamics , Humans , Hemodynamics/physiology , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aged , Female , Male , Aged, 80 and over , Heart Valve Prosthesis Implantation/methods , Echocardiography , Middle Aged , Prosthesis Design
8.
Crit Care Explor ; 6(5): e1083, 2024 May.
Article En | MEDLINE | ID: mdl-38694846

OBJECTIVES: This prospective cohort study aimed to investigate changes in intracranial pressure (ICP) and cerebral hemodynamics in infants with congenital heart disease undergoing the Glenn procedure, focusing on the relationship between superior vena cava pressure and estimated ICP. DESIGN: A single-center prospective cohort study. SETTING: The study was conducted in a cardiac center over 4 years (2019-2022). PATIENTS: Twenty-seven infants with congenital heart disease scheduled for the Glenn procedure were included in the study, and detailed patient demographics and primary diagnoses were recorded. INTERVENTIONS: Transcranial Doppler (TCD) ultrasound examinations were performed at three time points: baseline (preoperatively), postoperative while ventilated (within 24-48 hr), and at discharge. TCD parameters, blood pressure, and pulmonary artery pressure were measured. MEASUREMENTS AND MAIN RESULTS: TCD parameters included systolic flow velocity, diastolic flow velocity (dFV), mean flow velocity (mFV), pulsatility index (PI), and resistance index. Estimated ICP and cerebral perfusion pressure (CPP) were calculated using established formulas. There was a significant postoperative increase in estimated ICP from 11 mm Hg (interquartile range [IQR], 10-16 mm Hg) to 15 mm Hg (IQR, 12-21 mm Hg) postoperatively (p = 0.002) with a trend toward higher CPP from 22 mm Hg (IQR, 14-30 mm Hg) to 28 mm Hg (IQR, 22-38 mm Hg) postoperatively (p = 0.1). TCD indices reflected alterations in cerebral hemodynamics, including decreased dFV and mFV and increased PI. Intracranial hemodynamics while on positive airway pressure and after extubation were similar. CONCLUSIONS: Glenn procedure substantially increases estimated ICP while showing a trend toward higher CPP. These findings underscore the intricate interaction between venous pressure and cerebral hemodynamics in infants undergoing the Glenn procedure. They also highlight the remarkable complexity of cerebrovascular autoregulation in maintaining stable brain perfusion under these circumstances.


Cerebrovascular Circulation , Heart Defects, Congenital , Hemodynamics , Intracranial Pressure , Ultrasonography, Doppler, Transcranial , Humans , Infant , Prospective Studies , Female , Male , Intracranial Pressure/physiology , Heart Defects, Congenital/surgery , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/diagnostic imaging , Cerebrovascular Circulation/physiology , Ultrasonography, Doppler, Transcranial/methods , Hemodynamics/physiology , Cohort Studies , Fontan Procedure , Vena Cava, Superior/physiopathology , Vena Cava, Superior/diagnostic imaging
9.
Sensors (Basel) ; 24(9)2024 May 03.
Article En | MEDLINE | ID: mdl-38733027

Heart failure (HF) is a complex clinical syndrome associated with significant morbidity, mortality, and healthcare costs. It is characterized by various structural and/or functional abnormalities of the heart, resulting in elevated intracardiac pressure and/or inadequate cardiac output at rest and/or during exercise. These dysfunctions can originate from a variety of conditions, including coronary artery disease, hypertension, cardiomyopathies, heart valve disorders, arrhythmias, and other lifestyle or systemic factors. Identifying the underlying cause is crucial for detecting reversible or treatable forms of HF. Recent epidemiological studies indicate that there has not been an increase in the incidence of the disease. Instead, patients seem to experience a chronic trajectory marked by frequent hospitalizations and stagnant mortality rates. Managing these patients requires a multidisciplinary approach that focuses on preventing disease progression, controlling symptoms, and preventing acute decompensations. In the outpatient setting, patient self-care plays a vital role in achieving these goals. This involves implementing necessary lifestyle changes and promptly recognizing symptoms/signs such as dyspnea, lower limb edema, or unexpected weight gain over a few days, to alert the healthcare team for evaluation of medication adjustments. Traditional methods of HF monitoring, such as symptom assessment and periodic clinic visits, may not capture subtle changes in hemodynamics. Sensor-based technologies offer a promising solution for remote monitoring of HF patients, enabling early detection of fluid overload and optimization of medical therapy. In this review, we provide an overview of the CardioMEMS device, a novel sensor-based system for pulmonary artery pressure monitoring in HF patients. We discuss the technical aspects, clinical evidence, and future directions of CardioMEMS in HF management.


Heart Failure , Humans , Heart Failure/therapy , Heart Failure/physiopathology , Cardiology/methods , Monitoring, Physiologic/methods , Monitoring, Physiologic/instrumentation , Disease Management , Hemodynamics/physiology
10.
Sci Rep ; 14(1): 10242, 2024 05 03.
Article En | MEDLINE | ID: mdl-38702415

Cerebral infra-slow oscillation (ISO) is a source of vasomotion in endogenic (E; 0.005-0.02 Hz), neurogenic (N; 0.02-0.04 Hz), and myogenic (M; 0.04-0.2 Hz) frequency bands. In this study, we quantified changes in prefrontal concentrations of oxygenated hemoglobin (Δ[HbO]) and redox-state cytochrome c oxidase (Δ[CCO]) as hemodynamic and metabolic activity metrics, and electroencephalogram (EEG) powers as electrophysiological activity, using concurrent measurements of 2-channel broadband near-infrared spectroscopy and EEG on the forehead of 22 healthy participants at rest. After preprocessing, the multi-modality signals were analyzed using generalized partial directed coherence to construct unilateral neurophysiological networks among the three neurophysiological metrics (with simplified symbols of HbO, CCO, and EEG) in each E/N/M frequency band. The links in these networks represent neurovascular, neurometabolic, and metabolicvascular coupling (NVC, NMC, and MVC). The results illustrate that the demand for oxygen by neuronal activity and metabolism (EEG and CCO) drives the hemodynamic supply (HbO) in all E/N/M bands in the resting prefrontal cortex. Furthermore, to investigate the effect of transcranial photobiomodulation (tPBM), we performed a sham-controlled study by delivering an 800-nm laser beam to the left and right prefrontal cortex of the same participants. After performing the same data processing and statistical analysis, we obtained novel and important findings: tPBM delivered on either side of the prefrontal cortex triggered the alteration or reversal of directed network couplings among the three neurophysiological entities (i.e., HbO, CCO, and EEG frequency-specific powers) in the physiological network in the E and N bands, demonstrating that during the post-tPBM period, both metabolism and hemodynamic supply drive electrophysiological activity in directed network coupling of the prefrontal cortex (PFC). Overall, this study revealed that tPBM facilitates significant modulation of the directionality of neurophysiological networks in electrophysiological, metabolic, and hemodynamic activities.


Electroencephalography , Prefrontal Cortex , Spectroscopy, Near-Infrared , Humans , Prefrontal Cortex/physiology , Prefrontal Cortex/metabolism , Male , Adult , Female , Spectroscopy, Near-Infrared/methods , Low-Level Light Therapy/methods , Young Adult , Rest/physiology , Oxyhemoglobins/metabolism , Electron Transport Complex IV/metabolism , Hemodynamics/physiology , Nerve Net/physiology , Nerve Net/metabolism
11.
Sci Rep ; 14(1): 8984, 2024 04 18.
Article En | MEDLINE | ID: mdl-38637544

The influence of the aneurysm evolution on the hemodynamic characteristic of the blood flow inside the sac region is comprehensively investigated. By using the computational method, the blood flow through the vessel and aneurysm of the sac region is examined to find the role of aneurysm evolution on the wall shear stress, pressure, and risk of aneurysm rupture. Three different models of ICA aneurysms are chosen for the investigation of the aneurysm evolution at risk of rupture. Obtained data shows that the evolution of the aneurysm decreases the wall shear stress and pressure on the sac surface while an oscillatory index of blood increases on the aneurysm wall.


Aneurysm, Ruptured , Intracranial Aneurysm , Stroke , Humans , Hemodynamics/physiology , Stress, Mechanical
12.
Sci Rep ; 14(1): 8476, 2024 04 11.
Article En | MEDLINE | ID: mdl-38605063

Computational fluid dynamics (CFD) has been utilized to calculate hemodynamic parameters in anterior communicating artery aneurysm (AComA), which is located at a junction between left and right A1 and A2 segments. However, complete or half circle of Willis (CoW) models are used indiscriminately. This study aims to suggest recommendations for determining suitable CoW model. Five patient-specific CoW models with AComA were used, and each model was divided into complete, left-half, and right-half models. After validating the CFD using a flow experiment, the hemodynamic parameters and flow patterns in five AComAs were compared. In four out of five cases, inflow from one A1 side had a dominant influence on the AComA, while both left and right A1 sides affected the AComA in the remaining case. Also, the average difference in time-averaged wall shear stress between the complete and half models for four cases was 4.6%, but it was 62% in the other case. The differences in the vascular resistances of left and right A1 and A2 segments greatly influenced the flow patterns in the AComA. These results may help to enhance clinicians' understanding of blood flow in the brain, leading to improvements in diagnosis and treatment of cerebral aneurysms.


Intracranial Aneurysm , Humans , Circle of Willis , Hemodynamics/physiology , Cerebrovascular Circulation/physiology , Brain
13.
Circ Cardiovasc Imaging ; 17(4): e016104, 2024 Apr.
Article En | MEDLINE | ID: mdl-38567518

BACKGROUND: The Fontan operation is a palliative technique for patients born with single ventricle heart disease. The superior vena cava (SVC), inferior vena cava (IVC), and hepatic veins are connected to the pulmonary arteries in a total cavopulmonary connection by an extracardiac conduit or a lateral tunnel connection. A balanced hepatic flow distribution (HFD) to both lungs is essential to prevent pulmonary arteriovenous malformations and cyanosis. HFD is highly dependent on the local hemodynamics. The effect of age-related changes in caval inflows on HFD was evaluated using cardiac magnetic resonance data and patient-specific computational fluid dynamics modeling. METHODS: SVC and IVC flow from 414 patients with Fontan were collected to establish a relationship between SVC:IVC flow ratio and age. Computational fluid dynamics modeling was performed in 60 (30 extracardiac and 30 lateral tunnel) patient models to quantify the HFD that corresponded to patient ages of 3, 8, and 15 years, respectively. RESULTS: SVC:IVC flow ratio inverted at ≈8 years of age, indicating a clear shift to lower body flow predominance. Our data showed that variation of HFD in response to age-related changes in caval inflows (SVC:IVC, 2, 1, and 0.5 corresponded to ages, 3, 8, and 15+, respectively) was not significant for extracardiac but statistically significant for lateral tunnel cohorts. For all 3 caval inflow ratios, a positive correlation existed between the IVC flow distribution to both the lungs and the HFD. However, as the SVC:IVC ratio changed from 2 to 0.5 (age, 3-15+) years, the correlation's strength decreased from 0.87 to 0.64, due to potential flow perturbation as IVC flow momentum increased. CONCLUSIONS: Our analysis provided quantitative insights into the impact of the changing caval inflows on Fontan's long-term HFD, highlighting the importance of SVC:IVC variations over time on Fontan's long-term hemodynamics. These findings broaden our understanding of Fontan hemodynamics and patient outcomes.


Fontan Procedure , Heart Defects, Congenital , Humans , Child, Preschool , Child , Adolescent , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery , Vena Cava, Superior/physiology , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Liver/diagnostic imaging , Hemodynamics/physiology , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/surgery , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
14.
BMC Urol ; 24(1): 92, 2024 Apr 20.
Article En | MEDLINE | ID: mdl-38643097

PURPOSE: This study aimed to investigate the effects of two different positions on lower extremity hemodynamics during robot-assisted laparoscopic radical prostatectomy (RARP) for prostate cancer. METHODS: A total of 196 patients who underwent RARP in our hospital from February 2020 to March 2022 were included in this study. Among them, 98 patients who underwent surgery with the Trendelenburg position and split-leg position with calf reverse arch from March 2021 to March 2022 were assigned to the observation group, while 98 patients who underwent surgery with the Trendelenburg position and low lithotomy position from February 2020 to February 2021 were assigned to the control group. Using an ultrasound diagnostic instrument to detect the internal diameter, mean blood flow velocity, and mean blood flow volume of the left deep femoral vein at different times, such as the supine position (T0), after 5 minutes of placing the patient in the leg spilt or low lithotomy position (T1), after 5 minutes of pneumoperitoneum (T2), after 5 minutes of head-down tilt or head-down tilt and calf reverse arch (T3), 1.5 hours after the start of surgery (T4), before the removal of CO2 gas (T5), and before the patient left the operating room (T6). As well as the patency of deep venous blood flow in both lower extremities before leaving the operating room, RESULTS: After establishment of pneumoperitoneum, the internal diameter of the deep femoral vein increased significantly, while the mean blood flow velocity and mean blood flow volume decreased significantly in both groups(T0) (P<0.001). With the prolongation of surgical time, the impact on lower extremity hemodynamics in the observation group was smaller than that in the control group. From T2 to T6, the internal diameter of the femoral vein in the observation group was smaller than that in the control group, while the mean blood flow velocity and mean blood flow volume were increased compared to the control group (P<0.05). Before leaving the operating room, the patency of deep venous blood flow in the observation group was better than that in the control group (P=0.003). CONCLUSION: Placing patients in the Trendelenburg position and split-leg position with calf reverse arch during RARP for prostate cancer has a smaller impact on lower extremity hemodynamics than the low lithotomy position, and can relatively reduce the risk of postoperative deep vein thrombosis.


Laparoscopy , Pneumoperitoneum , Prostatic Neoplasms , Robotic Surgical Procedures , Robotics , Male , Humans , Hemodynamics/physiology , Prostatectomy , Lower Extremity , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery
15.
ACS Sens ; 9(4): 2166-2175, 2024 Apr 26.
Article En | MEDLINE | ID: mdl-38625680

Relying on the strong optical absorption of hemoglobin to pulsed laser energy, photoacoustic microscopy provides morphological and functional information on microvasculature label-freely. Here, we propose speckle variance photoacoustic microscopy (SV-PAM), which harnesses intrinsic imaging contrast from temporal-varied photoacoustic signals of moving red blood cells in blood vessels, for recovering three-dimension hemodynamic images down to capillary-level resolution within the microcirculatory tissue beds in vivo. Calculating the speckle variance of consecutive photoacoustic B-scan frames acquired at the same lateral position enables accurate identification of blood perfusion and occlusion, which provides interpretations of dynamic blood flow in the microvasculature, in addition to the microvascular anatomic structures. We demonstrate high-resolution hemodynamic imaging of vascular occlusion and reperfusion in the microvasculature of mice ears in vivo. The results suggest that our SV-PAM is potentially invaluable for biomedical hemodynamic investigations, for example, imaging ischemic stroke and hemorrhagic stroke.


Microscopy , Photoacoustic Techniques , Photoacoustic Techniques/methods , Animals , Mice , Microscopy/methods , Hemodynamics/physiology , Ear/blood supply , Ear/diagnostic imaging , Microvessels/diagnostic imaging , Erythrocytes , Microcirculation
16.
Comput Biol Med ; 174: 108476, 2024 May.
Article En | MEDLINE | ID: mdl-38636328

The reduced-order lumped parameter model (LPM) has great computational efficiency in real-time numerical simulations of haemodynamics but is limited by the accuracy of patient-specific computation. This study proposed a method to achieve the individual LPM modeling with high accuracy to improve the practical clinical applicability of LPM. Clinical data was collected from two medical centres comprising haemodynamic indicators from 323 individuals, including brachial artery pressure waveforms, cardiac output data, and internal carotid artery flow waveforms. The data were expanded to 5000 synthesised cases that all fell within the physiological range of each indicator. LPM of the human blood circulation system was established. A double-path neural network (DPNN) was designed to input the waveforms of each haemodynamic indicator and their key features and then output the individual parameters of the LPM, which was labelled using a conventional optimization algorithm. Clinically collected data from the other 100 cases were used as the test set to verify the accuracy of the individual LPM parameters predicted by DPNN. The results show that DPNN provided good convergence in the training process. In the test set, compared with clinical measurements, the mean differences between each haemodynamic indicator and the estimate calculated by the individual LPM based on the DPNN were about 10 %. Furthermore, DPNN prediction only takes 4 s for 100 cases. The DPNN proposed in this study permits real-time and accurate individualization of LPM's. When facing medical issues involving haemodynamics, it lays the foundation for patient-specific numerical simulation, which may be beneficial for potential clinical application.


Deep Learning , Hemodynamics , Models, Cardiovascular , Humans , Hemodynamics/physiology , Male , Female , Adult
17.
J Neural Eng ; 21(2)2024 Apr 25.
Article En | MEDLINE | ID: mdl-38621377

Objective.Dopaminergic treatment is effective for Parkinson's disease (PD). Nevertheless, the conventional treatment assessment mainly focuses on human-administered behavior examination while the underlying functional improvements have not been well explored. This paper aims to investigate brain functional variations of PD patients after dopaminergic therapy.Approach.This paper proposed a dynamic brain network decomposition method and discovered brain hemodynamic sub-networks that well characterized the efficacy of dopaminergic treatment in PD. Firstly, a clinical walking procedure with functional near-infrared spectroscopy was developed, and brain activations during the procedure from fifty PD patients under the OFF and ON states (without and with dopaminergic medication) were captured. Then, dynamic brain networks were constructed with sliding-window analysis of phase lag index and integrated time-varying functional networks across all patients. Afterwards, an aggregated network decomposition algorithm was formulated based on aggregated effectiveness optimization of functional networks in spanning network topology and cross-validation network variations, and utilized to unveil effective brain hemodynamic sub-networks for PD patients. Further, dynamic sub-network features were constructed to characterize the brain flexibility and dynamics according to the temporal switching and activation variations of discovered sub-networks, and their correlations with differential treatment-induced gait alterations were analyzed.Results.The results demonstrated that PD patients exhibited significantly enhanced flexibility after dopaminergic therapy within a sub-network related to the improvement of motor functions. Other sub-networks were significantly correlated with trunk-related axial symptoms and exhibited no significant treatment-induced dynamic interactions.Significance.The proposed method promises a quantified and objective approach for dopaminergic treatment evaluation. Moreover, the findings suggest that the gait of PD patients comprises distinct motor domains, and the corresponding neural controls are selectively responsive to dopaminergic treatment.


Brain , Parkinson Disease , Humans , Parkinson Disease/physiopathology , Parkinson Disease/drug therapy , Male , Female , Brain/physiopathology , Middle Aged , Aged , Hemodynamics/physiology , Hemodynamics/drug effects , Spectroscopy, Near-Infrared/methods , Nerve Net/physiopathology , Nerve Net/drug effects , Dopamine Agents/administration & dosage , Walking/physiology
18.
PLoS One ; 19(4): e0301350, 2024.
Article En | MEDLINE | ID: mdl-38626136

Bicuspid aortic valve (BAV) is the most common cardiac congenital abnormality with a high rate of concomitant aortic valve and ascending aorta (AAo) pathologic changes throughout the patient's lifetime. The etiology of BAV-related aortopathy was historically believed to be genetic. However, recent studies theorize that adverse hemodynamics secondary to BAVs also contribute to aortopathy, but their precise role, specifically, that of wall shear stress (WSS) magnitude and directionality remains controversial. Moreover, the primary therapeutic option for BAV patients is aortic valve replacement (AVR), but the role of improved post-AVR hemodynamics on aortopathy progression is also not well-understood. To address these issues, this study employs a computational fluid dynamics model to simulate personalized AAo hemodynamics before and after TAVR for a small cohort of 6 Left-Right fused BAV patients. Regional distributions of five hemodynamic metrics, namely, time-averaged wall shear stress (TAWSS) and oscillating shear index (OSI), divergence of wall shear (DWSS), helicity flux integral & endothelial cell activation potential (ECAP), which are hypothesized to be associated with potential aortic injury are computed in the root, proximal and distal ascending aorta. BAVs are characterized by strong, eccentric jets, with peak velocities exceeding 4 m/s and axially circulating flow away from the jets. Such conditions result in focused WSS loading along jet attachment regions on the lumen boundary and weaker, oscillating WSS on other regions. The jet attachment regions also show alternating streaks of positive and negative DWSS, which may increase risk for local tissue stretching. Large WSS magnitudes, strong helical flows and circumferential WSS have been previously implicated in the progression of BAV aortopathy. Post-intervention hemodynamics exhibit weaker, less eccentric jets. Significant reductions are observed in flow helicity, TAWSS and DWSS in localized regions of the proximal AAo. On the other hand, OSI increases post-intervention and ECAP is observed to be low in both pre- and post-intervention scenarios, although significant increases are also observed in this ECAP. These results indicate a significant alleviation of pathological hemodynamics post AVR.


Bicuspid Aortic Valve Disease , Heart Valve Diseases , Humans , Heart Valve Diseases/complications , Aorta/pathology , Aortic Valve/physiology , Hemodynamics/physiology , Stress, Mechanical
20.
Open Vet J ; 14(3): 852-865, 2024 Mar.
Article En | MEDLINE | ID: mdl-38682132

Background: Mares are the only companion animals simulating women in the large diameter of their follicles. Horses start reproduction at the age of three years, and some of them live for >30 years, so aging influences their reproductive capacity. Mares are sensitive to summer heat stress as they can sweat like humans. Aim: The current work aimed to study the effects of age (young versus senile), season (cold versus hot), and the hormonal treatments during embryo collection on the dominant and subordinate follicular dynamics and hemodynamics and circulating ovarian hormones in embryo donor mares ovulated twice spontaneously before inducing ovulation for flushing embryos. Methods: Spontaneous oestrous cycles were studied for young mares (<10 years; N = 6) or senile (>20 years; N = 5) during months of the cold season (November to April) and hot season (May to August). In young embryo donor mares, oestrous cycles after inducing ovulation and luteolysis were studied using Doppler ultrasound. Estradiol (E2), progesterone (P4), nitric oxide (NO), total cholesterol, and lactate dehydrogenase (LDH) were measured in blood serum. Results: A decrease in the dominant follicle antrum diameter (p > 0.05) and LDH (p = 0.016) was observed after inducing luteolysis in young embryo donor mares. Both human chorionic gonadotropin (hCG) and PGF2α treatments increased dominant follicle area (p = 0.0001), antrum area (p = 0.001), perimeter (p = 0.001), granulosa area (p = 0.0001), cholesterol (p = 0.0001), NO (p = 0.0001), and E2 (p = 0.0001). The dominant follicle area, antrum area, perimeter, color area, granulosa area, LDH, cholesterol, NO, and E2 increased (p = 0.0001) during the oestrous cycles of the hot season, but the circulatory % (p = 0.0001) declined. Senile mares had lower dominant follicle area (p = 0.002), antrum area (p = 0.0001), granulosa area (p > 0.05), LDH (p = 0.001), cholesterol (p = 0.0001), NO (p = 0.0001), and E2 (p = 0.0001) but higher circulatory % (p = 0.0001) and color area % (p = 0.023). The dominant follicle possesses the largest diameter, area, perimeter, granulosa area, and color area but the lowest circulatory % during spontaneous oestrous cycles, after inducing ovulation, or luteolysis with significant effects of the day of the spontaneous oestrous cycles on their dynamics and hemodynamics. Conclusion: During hot months, mares treated with hCG ovulated 24 hours later and prostaglandin-induced luteolysis was followed by new ovulation five days later. Follicles ovulated during the hot months were larger than those ovulated during the cold months and both had nearly the same color area %. Senile mares ovulated follicles with a lower area and antrum area but a higher color area %, so senile mares can be used as embryo or oocyte donors during the hot season.


Hemodynamics , Luteolysis , Ovarian Follicle , Seasons , Animals , Horses/physiology , Female , Luteolysis/physiology , Luteolysis/drug effects , Ovarian Follicle/physiology , Hemodynamics/physiology , Embryo Transfer/veterinary , Aging/physiology , Age Factors , Progesterone/blood , Estradiol/blood
...